TESTING FREQUENCY

 

As noted on Table 4, page 20 of AS/NZS 3760 2011. In brief, maximum interval between tests:

 

- Any new untagged or out-of-date tagged appliance – before use in any workplace

- Building sites and hire equipment - 3 monthly

- Factories, work areas and cleaning equipment - 6 monthly

- Schools and all other areas not mentioned - 1 yearly

- Residential areas of hotels, motels and rest homes - 2 yearly

- Some office and protected appliances - 5 yearly otherwise 1 yearly

 

All appliances in all workplaces must have a current test tag at all times

TESTING PROCESS

 

1. A visual inspection is carried out to identify any clear issues

 

2. Electrical testing of appliance to the rigorous standards of AS/NZS 3760 using calibrated test instruments.

 

3. All appliances passing the test process are tagged for easy identification.

 

 